Category
- Spectroscopy and Spectrometry » Optical Spectroscopy
Booking Details
Facility Management Team and Location
Facility Features, Working Principle and Specifications
Facility Description
The Fluorescence Spectrophotometer offers the ultimate sensitivity in fluorescence or emission profile of the complex under investigation. The instrument is easy to use and is controlled by FluorEssence software with Origin embedded for sophisticated data analysis.
Features/ Accessories:
- Source: 150 W Ozone-free xenon arc lamp
- Grating: 1200 groove/mm blazed at 330 nm (excitation) and 500 nm (emission), plane ruled. Automatic self-calibration of all wavelength drives and slits
- Monochromators: All reflective optics, Czerny-Turner spectrometers
- Water Raman S/N: 10,000:1 (FSD method). See Signal-to-noise ratio
- Detectors: Multialkali PMT emission detector (200-870nm)
- Liquid nitrogen cooled InGaAs detector (800-1550nm). It requires liquid N2 supply
- Rapid Peltier controlled single sample holder, -15° to 105°C water circulator
- Automated polarizers located at entrance and exit of sample compartment
- SS sample holder for thin film, powder samples, pellets etc
- FluorEssence software for control and data analysis
Principle:
---
Instructions for Registration, Sample Preparation, User Instructions and Precautionary Measures
User must discuss details about the sample and Experimental Parameters with the Technical Operator before the slot booking
- User must contact the Technical operator before booking slot and discuss the experimental parameter
- If Any reference material, solvents required are supplied by the user
- Provide solid samples in the fine powder form. Minimum required amount is approximately 1-2 gm.
- Liquid Samples are prepared by user in appropriate concentration required for the experiment. The required minimum amount is 2-3 ml.
In case any additional Chemicals/ materials required for recording the samples, Charges would be additional.
MS-DS (Material Safety Data Sheet) should be given along with samples. Samples should not be toxic or hazardous.
Charges for Analytical Services in Different Categories
Type of Analysis | IITB Users | Academic Institution | National R&D lab | Industries/ Non Govt Agencies |
Samples Charges per Hour in INR | 100 | 200 plus GST | 400 plus GST | 800 plus GST |
These charges are only recording charges for Pre-made samples. It does not involve any preparation of solutions or data interpretation.
Applications
- Qualitative and Quantitative analysis
- In Biotechnology
- Industries
- Environmental etc
Sample Details
No
No
No
No
No
No
No