Small Angle X-ray Scattering (SAXS)
Make
Xenocs SAS
Model
Xeuss 2.0
Facility Status
Working
Date of Installation
Facility Management Division
Sophisticated Analytical Instrument Facility (SAIF)

.

Category

  • Material Characterization » Structural Characterization

Booking Details

Booking available for
Internal and External Both
Available Equipment/ Mode of use
Small Angle X-ray Scattering (SAXS)
Wide Angle X-ray Scattering (WAXS)

Facility Management Team and Location

Faculty In Charge
Prof. Suparna Mukherji, head.saif@iitb.ac.in, office.saif@iitb.ac.in, 022- 25767691/2
Facility Manager
Dr. Gajender Saini, gsaini@iitb.ac.in, 022-21596481
Facility Operator
Ms. Vinita Anvekar, vinitas@iitb.ac.in, 022-21596867
Ms. Reshma Kadam, reshmas@iitb.ac.in, 022-21596867
Department
CRNTS
Lab Email ID
saxs@iitb.ac.in
Facility Location
410, 1st Floor, SAIF/CRNTS Building
Lab Phone No
022-21596867

Facility Features, Working Principle and Specifications

Facility Description

Facility Description

SAXS is an analytical characterization tool used to determine the structure of particle systems in terms of averaged sizes or shapes. The materials can be solid or liquid and they can contain solid, liquid or gaseous domains (so-called particles) of the same or another material in any combination. The method is accurate, non-destructive and usually requires only a minimum of sample preparation. Applications are very broad and include the metal, cement, oil, polymer, plastics, food and pharmaceutical industries and can be found in research as well as in quality control.

The state of the art machine just installed at SAIF IITB provides opportunities to analyze samples in various environments (ambient, low and high temperature, high pressure, and flow conditions).

Features Working Principle

X-rays are scattered at the electrons of the atomic shell. During the scattering process the electron is starts oscilating. It
becomes a dipol and a spherical wave is sent out. The wavelength and energy of the scattered wave does not change (elastic scattering).

By detecting x-rays scattered at different angles, different sample information is gained at different resolutions: SAXS has nanoscale resolution (good for samples 100-1 nm in size) while WAXS has atomic resolution (1-0.1 nm). Due to this, SAXS can be typically used to analyse larger scale bulk microstructure within a sample, while WAXS is more similar to x-ray diffraction.

Body Specification

X-ray Source: (Dual Source Module)
     GeniX3D Cu 30 Watts Cu tube with 50 KV  0.6mA current
     GeniX3D Mo, System shielded microfocus tube ( 50 Watts-50 kV/1 mA)
Optics: Single reflection multilayer parabolic mirror.
Slits: Single crystal scatter less slits ( S1, S2)
Detector: Eiger R 1M with vacuum feed through set high resolution hybrid pixel photon counting detector with a 75 µm pixel size
Automation: SpecFE based software to control motors slits, etc.
Data Acquisition: Foxtrot
Analysis Software: Xsact software provided by Xenocs for basic modelling, and SASfit software freeware provided.

Accessories :

      1)Capillary Flow Cell
      2)High temperature sample stage (-150 ⁰C to 350 ⁰C)
      3)Tensile Stage (0-200N) with humidity :
      4)Operating temperature range: -150 ⁰C to +250 ⁰C without the relative humidity Generator
      5)Multisample holders for powder and gels
      6)Multipurpose X-ray Temperature stage (-30⁰C to 150 ⁰C)
      7)Capillary cells of different sizes
      8)High Pressure cell GiSAXS module
      9)Shear Cell System ( ambient to 350 ⁰C)
 

Instructions for Registration, Sample Preparation, User Instructions and Precautionary Measures

Instructions for Registration

Kindly refer to the SAIF site for instruction for registration.

  • New users are requested to contact the SAXS lab before registration. 
  • Registration is online.
  • An appointment will be given as per queue and will be informed by email.
User Instructions and Precautionary Measures

Small Angle X-ray Scattering (SAXS) Charges excluding GST


 

 IndustryUniversityNational Lab/R&D'sIITB Internal Users 
SAXS Analysis6000/-2400/-3000 /-1200 /-Per Sample/Per Spectrum
 
With Flow Cell7000/-3000/-3500/-1500 /-Per Sample
 
With Shear Cell7000/-3000/-3500/-1500 /-Per Sample
 
At High Pressure10000/-4000/-5000/-2000 /-Per Sample
 
With Tensile stage with humidity10000/-4000/-5000/-2000 /-Per Sample
 

Charges for Analytical Services in Different Categories

Applications

1)The Properties of functional materials are strongly linked to their size, shape, interaction potential.

2)Functionalization of self-assembled structure.

3)Self assemblies of amphiphilic molecules called micelles are often utilized to stabilized water –insoluble functional substances  such as vitamins, perfumes and many more in water based products.

4)Pharmaceutical materials- Drug delivery systems are made of nano-carrier.

5)Food and nutrients- The structural information has become more and more important for developing better texture and functionalities that make food product wholesome.

6)Nano size inorganic particles are used in a wide verity of industrial fields such as cosmetics, paints and ceramics production.

7)Nano composites

8)Lipoproteins- SAXS often fast and precise measurement of LP particles using only small amount of samples.

 

Sample Details

Chemical allowed

NA

Allowed Substrate

NA

Gases allowed

NA

SOP, Lab Policies and Other Details

Publications