Semi Prep HPLC
Make
Shimadzu
Model
Preparative LC20AR HPLC
Facility Status
Working
Date of Installation
Facility Management Division
Institute Central Research Facilities (ICRF)

.

Category

  • Chromatography » Liquid Chromatography

Booking Details

Booking available for
Internal and External Both
Available Equipment/ Mode of use
Anaytical mode
Semi-Prep Mode

Facility Management Team and Location

Faculty In Charge
Prof. Pradeepkumar P. I
Prof. Nandita Madhavan
Facility Manager
Mr. Amol Hanumante
Facility Management Members
Prof. Pradeepkumar P. I
Prof. Nandita Madhavan
Prof. Ruchi Anand
Prof. Venkateswarlu Yarlagadda
Prof Kiran Kondabagil
Department
Chemistry
Lab Email ID
amol_ah@iitb.ac.in
Facility Location
Room No 212A, Chemistry Department Facility lab IV, First floor, Chemistry Building, IIT Bombay
Lab Phone No
022-25764159

Facility Features, Working Principle and Specifications

Facility Description

Facility Description

Analytical HPLC is used to determine sample purity and develop the purification method for semi-preparation chromatography. 

Semi preparative chromatography is carried out under low backpressures with bigger inner diameter columns and bigger particle size by passing mobile phases at high flow rates. It is used to purify and collect component of interest from all other contaminants in sample.

Features Working Principle

Specification / Features: 

1. It can be used for analytical as well as Semi-Prep analysis depending upon column used and mode selected.

2. LC-20AR Pump is capable of using Single solvent with max. flow upto 20mL/ min. 

3. Autosampler (SIL-20AC HT) is available for Analytical mode which introduces a precise aliquot of a sample solution from a sample container to HPLC column. For Prep Mode, sample is injected manually (max. 1mL) 

4. Fraction collector module (FRC-10A): it collects fractions even when the peak elution time varies, by catching the target component according to variations in the chromatogram. 

5. Column Oven (CTO-20AC): It can regulate the temperature in a range going from 10 degrees below room temperature to 85 °C. 

6. PDA detector (SPD-M20A): It can detect entire Wavelength range of 190 nm - 800 nm simultaneously 

7. Following Reverse Phase columns are available with system

a) Shim Pack GIST C18, 5um, 4.6 x 250 

b) Shim Pack GIST C18, 5um, 10 x 250

c) Shim Pack GIST C18, 5um, 20 x 250

Only compatible with water-soluble samples of biomolecules.

Instructions for Registration, Sample Preparation, User Instructions and Precautionary Measures

Instructions for Registration

User must contact Technical operator before booking the slot and discuss about experiment parameters

Instruction for Sample Preparation
  • . Only compatible with water-soluble samples of biomolecules.
  • Charges for chemicals/ reagents/solvents are extra or to be supplied by end user
User Instructions and Precautionary Measures
  • User is expected to know the details about method and column to be used. 
  • Internal Users are supposed to bring all chemicals required for the experiment.

Charges for Analytical Services in Different Categories

Usage Charges

Type of Analysis

IITB users

Academic Institutions

National R&D labs

Industries / Non Govt. Agencies

Charges per sample (each Single recording) for analytical Mode

100

300

750

1500

Charges for Semi-Prep mode run per hour 

 

250

1000

2000

4000

All charges in INR. These are only Instrument / recording charges. Charges for chemicals/ reagents/solvents are extra or to be supplied by end user. For external samples in addition to above basic charges, prevailing GST will be added.