MALDI-Autoflex-max Mass
Request form for external booking (Sample and analysis details)
Make
Bruker Daltonics GmbH & Co. KG
Model
autoflex maX™ MALDI TOF/TOF System
Facility Status
Working
Date of Installation
Facility Management Division
Centre for Sophisticated Instruments and Facilities (CSIF)

.

Category

  • Spectroscopy and Spectrometry » Mass Spectrometry

Booking Details

Booking available for
Internal and External Both
Available Equipment/ Mode of use
linear and reflection measurements in positive/negative ion mode for <10KDa and >10KDa

Facility Management Team and Location

Facility In Charge
Prof. Chidambar Kulkarni
chidambark@chem.iitb.ac.in
+91 22 2576 7186
Facility Manager
Rajesh G.
Facility Operator
Ruchi V.
Facility Management Members
Prof. Pradeepkumar P.I.
Prof. Kamendra Sharma
Prof. Ishita Sengupta
Prof. Prasenjiit Bhaumik
Department
Chemistry
Lab Email ID
hrmass@iitb.ac.in, rajeshg@chem.iitb.ac.in
Facility Location
Room No. 370, second Floor, Chemistry Department I.I.T. Bombay, Powai, Mumbai - 400076
Lab Phone No
022 25764159

Facility Features, Working Principle and Specifications

Facility Description

Facility Description

autoflex maX™ MALDI TOF/TOF System:

MALDI-Time-Of-Flight Mass Spectrometer for accurate mass determination and structure identification of bio-molecules.

Includes MALDI Perpetual™ ion source with self-cleaning device, extended pulsed ion extraction PAN™ mass range focusing; Bruker smart beam™-II laser technology for versatile applications with different sample preparation techniques; TOF analyser for linear and reflection measurements in positive/negative ion mode with integrated FlashDetector™ systems; MS/MS capability based on LIFT™ TOF/TOF technology; high-energy CID (Collision-Induced Dissociation) accessory Data System with 10 bit 5 Gs/s digitizer, WIN10 Operating-System, >=24| Widescreen-LCD-Display and Compass™ for Flex software package for MS control, data acquisition and processing

Features Working Principle

Features:

BioTools software allows the identification and detailed characterization of proteins and peptides using various types of mass spectra.

This includes database search of single spectra and combined MS and MS/MS datasets, the import of search results and further detection of modifications and mutations.

The RapiDeNovo module provides extensive de-novo sequencing capabilities.

BioTools also supports various top-down sequencing spectra types for intact protein characterization and enables the annotation and database search of these data.

PolyTools™ 2.0 is a program for the interpretation of MALDI mass spectra of polymers. It accepts peak lists and automatically detect the repeat unit, cation and end groups upon loading of the lists. It also calculates characteristic parameters of the chain length distribution like |molecular weight average|, |polydispersity| or |degree of polymerization|. It displays the results in tabular and graphical representation and can export both for further use in other programs. Kendrick Mass Defect (KMD) analysis of the data is possible as well and a variety of KMD analysis types/plots is available (KMD, KMD-RNKM, RKM and RKM-RNKM).

smartbeam II (DPSS) Used in autoflex max MALDI TOF TOF. The smartbeam I components (modulator, focus lens, pin hole) are inside the laser housing.

 

 

Body Specification

Wave length : 355 nm (diode pumped solid state laser)

Pulse duration : > 3ns

Pulse energy : < 100µJ

Repetition rate : 2000 Hz

Beam diameter: smartbeam pattern

Divergence : smartbeam pattern

Lifetime : 3.5 x109 shoots

Power supply : 100 - 240 V

Instructions for Registration, Sample Preparation, User Instructions and Precautionary Measures

Instructions for Registration
  •  External Users can come in-person or send your samples along with a letter from the Head / Guide on your College/Institute /Industry Original Letter Head for registration stating that the analysis is for research purpose to qualify for academic concession. 
  • The analytical data / spectra are provided only for research / development purposes. These cannot be used as certificates in legal disputes. 
  • Service charges are payable at prevailing rates. 
  • Samples, letter and payment should be sent in the same cover only. If Samples are received without covering letter the samples will be sent back to the user without any further intimation/notice. Separate Sample should be sent for different analysis. 
  • Samples are not analysed till Payment is received. 
  •  Please send the samples in quantity as mentioned. Samples are not recovered, unless a special request is made.
  •  Radio -active material should be clearly mentioned and handed over personally.
  •  Unstable and explosive compounds are not accepted for analysis.   
  •  Kindly fill separate sample submission forms for different sample type with complete
    information as requested in the sample submission form.
  • Also please fill the check list for the tolerance for common buffer compounds / solvents
    used during sample preparation / processing attached with this form (pg-3).
  • SDS-PAGE image for proteins is mandatory and for other sample types mass information of
    any other suitable data will be accepted.
  • Zip-tipping of samples is must for all peptide analysis and also for proteins wherever
    required (will be confirmed by the MALDI staff in charge)
Instruction for Sample Preparation

INSTRUCTIONS FOR SAMPLE PREPARATION :
• Experiments should be discussed with the facility in-charge before appointment.
• Purity of samples is extremely important for generating good data.
• Protein concentrations should be measured accurately before starting the experiment.
• The molecular weight (SDS IMAGE copy mandatory)as well as the pI of the proteins should
be known before analysis.
• Zip-tipping of samples must for all peptide analysis and also for proteins wherever required (will be confirmed by the MALDI staff in charge).
• Appointments will be provided as per que and the user will be informed about the same.
• Kindly perform literature review on similar work and accumulate as much information as
possible for good quality data.
• Any query regarding your MALDI experiment can be emailed on rajeshg@chem.iitb.ac.in

 

Whenever the prepared samples are used in the publications appropriate acknowledgement of usage of Chemistry, IIT Bombay MALDI facility must be mentioned. The details should be forwarded to rajeshg@chem.iitb.ac.in

User Instructions and Precautionary Measures

General Instructions for MALDI TOF/TOF Users:
Mass spectrometry is highly sensitive to various contaminants, such as PEG (poly ethylene glycol), keratin and various salts. In order to reduce PEG and keratin in the sample it is recommended to use powder free nitryl gloves. Please supply the sample in a low-salt buffer (less than 10 mM).

  • Use fresh solutions. All solvents should be pure as possible. HPLC grade is recommended.
  • Avoid volatile solvents! Several of these solvents are common in protein chemistry: glycerol, polyethylene glycol,b-mercaptoethanol,triton-X-100,DMSO,DMF,etc.
  • Scalpel, pipette tips and tubes should be clean. Use original Eppendorf tubes. Since the solvents can leach the plastics and polymer contamination can occur.
  • Sequencing grade trypsin is recommended

It is recommended to use the Coomassie / silver staining Standard  protocol.

Levels of buffers and detergents which exceed the following limits will probably cause noticeable degradation of the spectrum

Phosphate Buffer  >50 mM

Ammonium Bicarbonate  > 30 mM

Tris Buffer  >100 mM

Guanidine  >1M

Detergent(e.g. Trition-X)  0.1%

SDS  0.01%

Alkali  metal salts  >1M

Glycerol  >1%

Sodium azide  >1 mM

Charges for Analytical Services in Different Categories

Usage Charges

Charges for External Users: (a) Basic charges + (b) GST*

(a) Basic charges:

Type of samples

 

Type of analysis

 

IITB Users

( in ₹ )

Academic institutes

( in ₹ )

National R &D lab`s

 (in ₹ )

Industries / Non Govt. Agencies

 (in ₹ )

Small Molecules

MS analysis

50

100

500

1000

   Intact Protein

MS analysis

200

400

1000

2000

Oligonucleotides

MS analysis

200

400

1000

2000

Peptide mass fingerprinting 

MS analysis

200

400

1000

2000

MS/MS analysis

300

600

 

1500

3000

 

(b)GST*(rate as on 1.8.2017):

1) If the recipient of the report is from Maharashtra: 9% SGST and 9% CGST 2) If the recipient of the report is from outside Maharashtra: 18% IGST

 

  • Payment Terms: 100% Advance

Payment Bank Details for Electronic Transfer:

Account Name: Indian Institute of Technology

Bombay Bank Name: State Bank of India, IIT Powai Branch, Mumbai-400076, India

Account Number: 10725729173

IFSC Code: SBIN0001109

MICR Code: 400002034 Branch Code: 1109

SWIFT Code: SBININBB519

Bank Contact Number: +91-22-2572-1103

 

 

 

Applications

  • Molecular weight determination of intact proteins
  • Partial protein sequencing
  • Protein identification
  • N-terminal sequencing
  • Small molecule detection
  • Nucleic acid and oligo nucleotide detection
  • Polymer detection

Sample Details

Gases allowed

NO

SOP, Lab Policies and Other Details

Publications