Category
- Synthesis ยป Biochemical Synthesis
Booking Details
Facility Management Team and Location
Facility Features, Working Principle and Specifications
Facility Description
It is used to prepare Solid-phase peptide synthesis (SPPS) which involves the successive addition of protected amino acid derivatives to a growing peptide chain immobilized on a solid phase, including deprotection and washing steps to remove unreacted groups and also side products.
Specification / Features:
1. Scale of Synthesis: 0.005 - 1.0mmol per reaction vessel (Maximum 2 Reaction Vessels at a time)
2. Heating method: Controlled induction heating, configurable to the number of RVs
3. Agitation method: Argon bubbling - adjustable, and/or option oscillating shaker mixing
4. Reaction vessel volume: Plastic, disposable: 10 mL Borosilicate glass: 10 mL, 25 mL, 40 mL
5. Number of solvent positions/sizes: upto 8 solvents
6. Number of amino acid positions: 27 amino acid bottles positions
7. Control interface: Proprietary PurePep Chorus control software, internal CPU, tablet (wireless connection)
It is used to prepare Solid-phase peptide synthesis (SPPS) which involves the successive addition of protected amino acid derivatives to a growing peptide chain immobilized on a solid phase, including deprotection and washing steps to remove unreacted groups and also side products.
Instructions for Registration, Sample Preparation, User Instructions and Precautionary Measures
- User must contact the Technical operator before booking slot and discuss the experimental parameter
- User Should give detailed information about method, Resin, Chemicals to be used.
- Chemicals/Reagents/ solvents are to be supplied by end user.
- If end users do not supply chemicals, reagents/solvents, in addition to above basic charges, there will be additional charges as per the peptide sequence. The end-user will be provided a quotation for the same.
- User Should give detailed information about method, Resin, Chemicals to be used.
- Chemicals/Reagents/ solvents are to be supplied by end user.
- Internal User must get trained before using this Instrument.
- Additional Nitrogen gas charges: Rs 750 per day (Minimum charges are Rs 750)
- If end users do not supply chemicals, reagents/solvents, in addition to above basic charges, there will be additional charges as per the peptide sequence. The end-user will be provided a quotation for the same.
Charges for Analytical Services in Different Categories
.Charges:
Type of Analysis | IITB users | Academic Institutions | National R&D labs | Industries / Non Govt. Agencies |
Charges per day
| 500 | 1000 | 2500 | 10000 |
All charges in INR
Additional Nitrogen gas charges: Rs 750 per day (Minimum charges are Rs 750)
These are only Instrument recording charges. Chemicals/Reagents/ solvents are to be supplied by end user. For external samples in addition to above basic charges, prevailing GST will be added
Applications
Sample Details
Yes
Yes