MPMS3 system is made by QD  with CCR based.
Make
Quantum Design
Model
SQUID-MPMS3
Facility Status
Working
Date of Installation
Facility Management Division
Centre for Sophisticated Research Facilities (CSIF- IoE Funded*)

.

Category

  • Material Characterization » Magnetic Characterisation

Booking Details

Booking available for
Internal and External Both
Available Equipment/ Mode of use
dc-Magnetization and ac-susceptibility

Facility Management Team and Location

Faculty In Charge
Prof. Maheswaran Shanmugam Dept. of Chemistry Email: eswar@chem.iitb.ac.in Ph: +91 22 2576 7187
Co-convenors
Prof. Ramaswamy Murugavel Dept. of Chemistry Email: muruks@iitb.ac.in Ph: +91 22-2576 7163
Facility Manager
Baidyanath Sahu, Email: 30006098@iitb.ac.in
Facility Operator
Baidyanath Sahu, Email: 30006098@iitb.ac.in
Facility Management Members
Prof. M. Shanmugam, eswar@chem.iitb.ac.in, +91 22 2576 7187
Prof. R. Murugavel, rmv@chem.iitb.ac.in, +91 22 2576 7163
Prof. G. Rajaraman, rajaraman@chem.iitb.ac.in,+91 22 2576 7183
Prof. C. Subramaniam, csubbu@chem.iitb.ac.in, +91-22 2576 7194
Prof. Sourabh Lodha, slodha@ee.iitb.ac.in, +91-22-2576-7460
Prof. K. G Suresh, suresh@phy.iitb.ac.in, +91-22-25767573
Prof. A. V. Mahajan, mahajan@phy.iitb.ac.in, +91-22-25767573
Prof. Srinivasan Ramakrishnan, srini@chem.iitb.ac.in, +91 22 2576 7197
Prpf. Dipanshu Bansal, dipanshu@iitb.ac.in, +91-22-25767508
Department
Chemistry
Lab Email ID
mrflab@chem.iitb.ac.in
Facility Location
Short Circuit Building Near EMD

Facility Features, Working Principle and Specifications

Facility Description

Facility Description

Quantum Design’s SQUID-MPMS3 is a high sensitive magnetization measurement system. It can be used for variable temperature range 1.8 K to 400 K and magnetic field value of ± 7 Tesla. Ac-susceptibility can be measured upto 1 kHz frequency. 

Instructions for Registration, Sample Preparation, User Instructions and Precautionary Measures

Instructions for Registration

User will apply online.

An appointment will be given as per queue and will be informed by email.

New users are requested to contact facility manager of lab before registration.

Instruction for Sample Preparation

Solid sample is required for all measurements.

For ac- and ac- magnetization, solid and powder sample will be required. The sample weight must be 10 to 50 mg.

Note: Liquid sample is not allowed. 

Charges for Analytical Services in Different Categories

Applications

Sample Details

SOP, Lab Policies and Other Details

Publications