Facility Features, Working Principle and Specifications
The FEI Quanta 200 scanning electron microscope is a versatile microscope with a tungsten electron source and three modes of operation. High vacuum (HV) mode allows analysis of electrically conducting and non conducting samples (non conducting samples can be analysed after sputter coating) Low Vacuum & ESEM modes allow analyzing biological and insulating samples without coating.
Resolution : 3.0 nm resolution at 30 kV Magnification : 25X to 20,000X Accelerating Voltage : 200 V to 30 kV Vacuum Modes : High Vacuum, Low vacuum, ESEM Mode
Instructions for Registration, Sample Preparation, User Instructions, Precautionary Measures and Charges
- An appointment will be given as per queue and will be informed by email.
- New users are requested to contact ESEM lab before registration.
- At least 24 hours prior information should be given to ESEM lab if users want to cancel/postpone the slot.
- Medium for Dispersion Ethanol /Methanol / Water /Iso-propyl alcohol. Any other medium should be provided by the user. Dispersion will be done by ultrasonication.
- Kindly mark the edge of the sample to be observed for Cross section.
- Base of the sample should be flat for mounting on sample holder.
- Sample preparation if any should be done at user end (cutting the sample for CS, freeze fracturing, sample fixation for biological samples, staining of samples, oven drying should be done by the user)
- For any further query, kindly contact on Email: esem@iitb.ac.in, Contact: 022 21596862
1. A requisition letter addressed to Head, SAIF along with a printout of electronic fund transfer (NEFT) proof should be sent by post or submitted in
person to SAIF office, IIT Bombay, Powai, Mumbai-400076.
2. If you are sending samples by post please mention sample details:
a. Expected features you are looking for (send a representative picture if available).
b. Morphology & expected size
c. Required Magnification(range).
d. Nature of sample (conducting OR non conducting)
e. Solvent required for dispersion (Water,IPA,Ethanol,Acetone)
3. Once we receive the requisition letter and advance payment, your appointment will be scheduled as per the queue.
4. The users will be informed about their date and time of slot by e-mail.
6. The sample size should be less than 12.5 mm x 12.5 mm and base of the sample should be flat for mounting on sample holder.
7. We prefer that you or your representative, who knows/understands the sample/material should be present on the day of appointment.
8. Before proceeding further, please review How to Use Facility and Payment Procedure for more information.
Environmental Scanning Electron Microscope (ESEM) Samplewise format, Charges GST for External users:
|
Applications
- Materials Science/Metallurgy
- Fractography (samples which have bigger dimensions can be analysed)
- Micro drilling and cutting tools
- Dental and medical
- Corrosion
- Polymer Science
- Energy Science/Engg.
- Biological and life sciences
- Semiconductors
- Civil and Earth Sciences
- Nanotechnology
- Ceramics
- Pharmaceuticals
Sample Details
NA
NA
Sample form:Powder/Pellet/Suspension/On glass substrate/Film
The bulk sample should be less than 12 mm x 12 mm and base of the sample should be flat for mounting on sample holder.
NA
NA
NA